Hi everyone,

Let's  say we have two DC1 under the control of same NSX manger. A  overlay segment-100 has been stretched between two DC1 so we have E-W traffic between DC1 and DC2.

SEG-A100 is logical switching segment with subnet 100.100.100.0/24,  Same hosts say H1 100.100.100.100  can generate CIFS/NFS file transfer traffic and it can  generate light  traffic such as ssh.  Underlay network is configured to regard AF11 marked traffic as " BulK" traffic class while traffic marked with C2 as " OAM" traffic class.

How can use mark traffic in NSX? I look at segment profile option, but it does not provide any option to factor in IPS, layer 4 info  to set DSCP.

Much appreciated!!

0 Kudos
1 Solution

Accepted Solutions
chandrakm
VMware Employee
VMware Employee
Jump to solution

To my knowledge that option is not available yet.

Cheers,
Chandra | 2xVCIX | CCIE | TOGAF
Please KUDO helpful posts and mark the thread as solved if answered

View solution in original post

4 Replies
chandrakm
VMware Employee
VMware Employee
Jump to solution

You should be able to set DSCP and COS under NSX switching profiles in NSX manager mode. Please refer below:

 

https://docs.vmware.com/en/VMware-NSX/4.1/administration/GUID-574B3FE2-5ABF-4AF4-BF0E-A86E17D0AF19.h...

https://docs.vmware.com/en/VMware-NSX/4.1/administration/GUID-D6396BD7-6A9B-41D0-AD7D-E67CF5542524.h...

 

Cheers,
Chandra | 2xVCIX | CCIE | TOGAF
Please KUDO helpful posts and mark the thread as solved if answered
zeebahi
Enthusiast
Enthusiast
Jump to solution

Thanks you so much.

It is same thing in  policy mode under QOS profile which is under segment profile.

But I do not any option where we can define IPS, TCP/UDP port number as  a criteria to set DSCP.

Example 1.1.1.1 TCP 23 should be marked as DSCP  EF.  I do not see anywhere where I can define these parameters in QOS profile.

 

 

0 Kudos
chandrakm
VMware Employee
VMware Employee
Jump to solution

To my knowledge that option is not available yet.

Cheers,
Chandra | 2xVCIX | CCIE | TOGAF
Please KUDO helpful posts and mark the thread as solved if answered
zeebahi
Enthusiast
Enthusiast
Jump to solution

Appreciated!!

0 Kudos